The Schneider Electric Galaxy VS is a highly efficient, easy to deploy, modular 20-100 kW three-phase uninterruptible power supply (UPS) with flexible operating modes for IT, data centers, and business-critical applications.
Providing the best performance in a high-density design, Galaxy VS UPS is the right solution to optimize total cost of ownership. It reduces your utility costs with industry-leading efficiency in normal operating mode and ECOnversion mode, and simplifies the right-sizing of your UPS with unity power factor. Galaxy VS also delivers outstanding availability, with the full protection of normal operating mode throughout a wide input voltage tolerance window. The UPS quickly restores battery runtime, with our innovative fast battery recharge feature, and continues its leadership in modern power protection with the long-life Schneider Electric lithium-ion battery solution.
Risk management is simple with the Galaxy VS UPS’s modular, lightweight design, which ensures full front service access. The included smartphone app delivers peace of mind with anytime, anywhere access to real-time UPS status, alerts, and predictive analysis through the EcoStruxure IT platform. Delivering the best power protection in the industry, Galaxy VS is the ideal backbone for your critical infrastructure.
Galaxy VS – Design Benefits
Full front access for installation and maintenance
No rear access needed, no shadow footprint
Highly compact design
High-density technology, particularly adapted for installation in confined spaces
Robust charger
Recharge batteries 2 to 3x faster by using up to 40% of the system power for the charger
Dust Filters
Two possible types depending on the protection needed; customer-replaceable
Reinforced design
- Dust filter, conformal-coated boards
- Short-circuit: 65kAIc protection
- Interferences: EMC category C2
- Seismic (with option kit)
Casters & lightweight design
Allows for easy maneuverability
Green Premium Solution
Sustainable business performance, by design
Intelligence Module
“System brain” contains critical control and signal wires interfaces"
Power Modules
Safe-swap, slide in/slide out modules with rear connector. Includes fan box for easy replacement. Superb core performances (PF)1, Hi-density, Hi-efficiency).
Static Switch Module
With its modular design, it can be replaced without installing an External Bypass
Network management
Ethernet and Modbus connection included in standard; 8 dry contacts permit to monitor the system
Internal Maintenance Bypass
Simplifies service operations, eliminates risk of error
Large cabling section
Makes installation and cabling work particularly simple
- Copper or Alu cables
- Suitable for 3- or 4-wire installation (with or without neutral) for more flexibility